Filter frame MA03  

Type
MA03 series
Dimensions
L x W x H in cm
Filter area
Performance
m³/day *
Quantity
MCXL
Quantity
MC03
MA03-1 36.5 x 36.5 x 86 3.5 2.2   1
MA03-2 36.5 x 36.5 x 140 7 4.4   2
MA03-XL 43.6 x 34.5 x 64.5 7 4.4 1  
MA03-XL2 43.6 x 34.5 x 113.0 14 10 2  
* Values depend on wastewater condition


MA03-1
MA03-1

The filterhousing MA03 is the proven series for decentral, small plants. They are chosen especially for small sewage and greywater treatment plants of the Aquacell series. One of the main design aspects is the easy mounting ability through man holes.

The aeration of the MicroClear® filter takes place with mid sized air bubble diffusors with an optimized flow channel. Thus even for these small units, a high cleaning efficiency and a low energy consumption is natural.


MA03-XL2
MA03-XL2

Advantages:

  • especially designed for under ground tanks and plastic tanks with man hole
  • flexibly configurable, simple maintenance
  • assembly/disassembly even under difficult site conditions
  • maintenance free, efficient aeration system
  • mid-size bubble aeration, lowest energy consumption for the entire plant


MA03-1

MA03-1

Typical application: small clarification plants for 4 persons and grey-water plants

Throughput (2 chemical cleanings per year)*: 2.5 m³/day

Throughput (1 chemical cleaning per year)*: 1.25 m³/day

*the throughput applies to household wastewater and depends on the wastewater's specific parameters

MA03-1 technical datasheet (PDF)



MA03-2

MA03-2

Typical application: small clarification plants for up to 8 persons and grey-water plants, water level >1.7 m

Throughput (2 chemical cleanings per year)*: 5 m³/day

Throughput (1 chemical cleaning per year)*: 2.5 m³/day

*the throughput applies to household wastewater and depends on the wastewater's specific parameters

MA03-2 technical datasheet (PDF)



MA03-XL

MA03-XL

Typical application: small clarification plants for up to 8 persons and grey-water plants. For limited tank height, water level > 1 m

Throughput (2 chemical cleanings per year)*: 5 m³/day

Throughput (1 chemical cleaning per year)*: 2.5 m³/day

*the throughput applies to household wastewater and depends on the wastewater's specific parameters

MA03-XL technical datasheet (PDF)



MA03-XL2

MA03-XL2

Typical application: small clarification plants for up to 16 persons and grey-water plants. For limited tank height, water level > 1 m

Throughput (2 chemical cleanings per year)*: 10 m³/day

Throughput (1 chemical cleaning per year)*: 5 m³/day

*the throughput applies to household wastewater and depends on the wastewater's specific parameters

MA03-XL2 technical datasheet (PDF)


 